Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
EuroIntervention ; 20(6): e389-e398, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506736

RESUMO

BACKGROUND: Drug-coated balloons (DCBs) are important treatment options for coronary artery disease; however, randomised controlled trials comparing various DCB technologies are sparse, and further investigations are needed. AIMS: This preclinical study aimed to histologically and biologically compare the drug effects and safety of a low-dose paclitaxel-coated DCB (PCB; AGENT), a regular-dose PCB (SeQuent Please NEO) and a sirolimus-coated DCB (SCB; MagicTouch). METHODS: The DCBs were inflated in the healthy iliac arteries of 18 rabbits, which were euthanised after 28 days. The treated iliac arteries and distal skeletal muscles were histopathologically evaluated, and drug concentrations were measured. RESULTS: In the histopathological evaluation, the medial smooth muscle cell loss score regarding depth, an indicator of drug efficacy, was significantly higher with AGENT and SeQuent Please NEO than with MagicTouch (4.0 [3.6-4.0] vs 3.7 [3.7-4.0] vs 2.2 [2.0-2.4]), with significant differences in comparisons between AGENT and MagicTouch (p<0.01) and between SeQuent Please NEO and MagicTouch (p<0.01). AGENT and SeQuent Please NEO showed comparable drug concentrations in the treated artery (p=0.61). In contrast, the drug concentrations in distal skeletal muscles were the highest for MagicTouch, followed by SeQuent Please NEO and AGENT (28.07 [13.19-52.46] ng/mg vs 0.66 [0.22-3.76] ng/mg vs 0.25 [0.04-3.23] ng/mg, respectively). CONCLUSIONS: This study demonstrated that PCBs might have higher efficacy and lower drug concentrations in distal skeletal muscles than the MagicTouch SCB. The efficacy of the AGENT low-dose PCB and the SeQuent Please NEO regular-dose PCB was comparable.


Assuntos
Doença da Artéria Coronariana , Bifenilos Policlorados , Animais , Coelhos , Coração , Artérias , Paclitaxel/farmacologia , Sirolimo/uso terapêutico
2.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38439540

RESUMO

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Correção Endovascular de Aneurisma , Endoleak/etiologia , Stents , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia
3.
Eur Heart J Case Rep ; 7(8): ytad353, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559783

RESUMO

Background: Several side effects have been reported after mRNA COVID-19 vaccinations. Nonetheless, the risk of pulmonary hypertension (PH) is rarely reported. Most cases with acute PH following vaccination were due to macropulmonary embolism secondary to deep vein thrombosis. However, acute PH due to microthrombus formation after COVID-19 vaccination has not been reported before, although a microthrombus has been considered to lead to the dysfunction of multiple organs, particularly in patients infected with COVID-19. Case summary: A 63-year-old woman without any past medical history presented to our hospital with facial and bilateral pedal oedema and progressive dyspnoea on exertion. Her symptoms began the day after her second COVID-19 vaccination and developed gradually, which prompted her to seek consultation in our hospital 6 weeks later. An echocardiogram revealed substantially elevated right heart pressure, and cardiac catheterization revealed high pulmonary artery pressure (mean PAP, 30 mmHg). Contrast-enhanced computed tomography and venous echography revealed no apparent thrombus, and ventilation/perfusion (V/Q) scintigraphy revealed no V/Q mismatch. However, elevated D-dimer indicated the presence of a coagulation-fibrinolysis system in her body; thus, heparin therapy was initiated intravenously on Day 3 for 4 days, followed by direct oral anticoagulants ended on Day 16. Her symptoms substantially improved as her D-dimer level decreased, and a follow-up cardiac catheterization on Day 14 revealed a decline in mean PAP (15 mmHg). Discussion: Our case suggests that the presence of acute PH is likely due to microangiopathy. Further studies are required to reveal the relationship between immune responses and microthrombus formation after COVID-19 vaccination.

4.
Eur J Vasc Endovasc Surg ; 66(5): 722-729, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37516380

RESUMO

OBJECTIVE: Poor below knee (BTK) runoff is a predictor of stent failure after endovascular femoropopliteal artery treatment; however, lack of pathological evaluation has prevented characterisation of stent failure. The study aimed to investigate the impact of poor BTK runoff and the antithrombotic effect of the polymer of fluoropolymer coated paclitaxel eluting stents (FP-PESs) in a healthy swine femoropopliteal artery model. METHODS: FP-PESs and bare metal stents (BMSs) and FP-PES and polymer free paclitaxel coated stents (PF-PCSs) were implanted in the bilateral femoral arteries of healthy swine (n = 6, respectively) following coil embolisation in both tibial arteries to induce poor BTK runoff. Histological assessment and intravascular imaging device evaluation were performed at one month. The Japanese Association for Laboratory Animal Science approved the study protocol (reference number: IVT22-90). RESULTS: Optical coherence tomography showed significantly lower percent area stenosis in FP-PES compared with BMS (37.3%, [interquartile range (IQR), 25.6 - 54.3] % vs. 92.5% [IQR, 75.5 - 96.1] %, respectively, p = .031), and PF-PCS (8.3% [IQR, 4.5 - 27.0] % vs. 31.2% [IQR, 23.3 - 52.2] %, respectively, p = .031). Histopathological evaluation demonstrated that thin fibrin attachment without re-stenosis was the most dominant neointimal tissue characteristic in FP-PES. On the other hand, neointimal tissue characteristics with significant restenosis of BMS and PF-PCS were mainly organising or organised thrombus. CONCLUSION: Organising and or organised thrombus attachment due to poor BTK runoff was the main cause of in stent restenosis of the swine femoral artery. FP-PES demonstrated the least percent area stenosis, suggesting the importance of the antithrombotic effect of polymer.


Assuntos
Stents Farmacológicos , Trombose , Suínos , Animais , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Polímeros de Fluorcarboneto , Fibrinolíticos , Constrição Patológica , Stents , Polímeros , Paclitaxel , Neointima , Trombose/etiologia , Resultado do Tratamento
5.
J Endovasc Ther ; : 15266028231161215, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36951275

RESUMO

BACKGROUND: A recent meta-analysis of randomized control trials demonstrated a significantly higher risk of major amputation in patients treated with drug-coated balloons (DCBs) compared with standard treatment, especially in high-dose paclitaxel-coated DCBs. Distal particulate embolization after DCB use was considered a potential cause of the higher incidence of major amputation. The current study aimed to histologically and biologically compare biologic drug effect and distal particulate embolization in 3 DCBs (a high-dose paclitaxel-coated DCB [IN.PACT Admiral] and 2 low-dose paclitaxel-coated DCBs [Ranger and Lutonix]). METHODS AND RESULTS: The DCBs were inflated in the healthy descending aortas of 18 rabbits, followed by euthanasia 28 days after the procedure. The treated descending aorta and distal skeletal muscles were histopathologically evaluated, and paclitaxel concentrations were measured. The paclitaxel concentration of the treated lesion was highest for Ranger, followed by IN.PACT and Lutonix (Ranger vs IN.PACT vs Lutonix: 1089 [745-2170] pmol/mg vs 638 [160-2075] pmol/mg vs 25 [10-304] pmol/mg, respectively; p<0.0001). In the histopathological evaluation, the angle of severe medial smooth muscle cell loss was largest for Ranger followed by IN.PACT and Lutonix (12.8 [8.0-20.4] degree vs 1.4 [1.2-5.2] degree vs 0.8 [0.5-2.5] degree, respectively), with significant differences for Ranger vs IN.PACT (p=0.007) and Ranger vs Lutonix (p=0.002). However, paclitaxel concentrations of distal skeletal muscles were lowest for Lutonix, followed by Ranger and IN.PACT (12 [1-58] pmol/mg vs 15 [13-21] pmol/mg vs 42 [19-108] pmol/mg, respectively, p<0.0001). The numbers of arteries with downstream DCB effects were highest for IN.PACT, followed by Ranger and Lutonix (Ranger vs IN.PACT vs Lutonix, 3 [3-4] vs 4 [3-7] vs 2 [1-2], respectively), which was consistent with the measured tissue paclitaxel concentrations. CONCLUSION: These findings suggest that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization, making it a good treatment option for patients with peripheral artery disease among the 3 DCBs evaluated in the current study. Further clinical head-to-head comparisons with larger numbers of patients are needed to explore which DCB is the most effective and safe treatment option.Clinical Impact:The findings of the current preclinical study suggests that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization making it a good treatment for patients with intermittent claudication and chronic limb-threatening ischemia.

7.
Cardiovasc Interv Ther ; 38(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36609899

RESUMO

BACKGROUND: Excimer laser is used to treat coronary artery disease, especially in case of lesions with thrombus and in-stent restenosis (ISR). However, there are no in vivo preclinical studies that have evaluated the pathological reactions of the vessel wall after excimer laser ablation. METHODS: Bare-metal stents were placed in the external iliac arteries of six healthy rabbits. Twenty-eight days later, excimer laser ablation was performed with low-power (45 (fluency)/25 (rate)) in one side, and high-power (60/40) in the opposite side, followed by optical coherence tomography (OCT) evaluation. Rabbits were sacrificed 15 min after the procedure, and histological assessment was performed. RESULTS: Morphometry analysis of OCT showed similar stent and lumen size between low-power and high-power group. Histological evaluation suggested endothelial cell loss, fibrin deposition, and tissue loss. The low-power group showed significantly less pathological changes compared with the high-power group: angle of endothelial cell loss, 32.4° vs. 191.7° (interquartile range, 8.8°-131.7° vs. 125.7°-279.5°; p < 0.01); fibrin deposition, 1.1° vs. 59.6° (0.0°-70.4° vs. 31.4°-178.4°; p = 0.03); and tissue loss 0.0° vs. 18.2° (0.0°-8.7° vs. 0.0°-42.7°; p = 0.03). CONCLUSIONS: The pathological changes in neointima were more prominent after high-power excimer laser ablation than after low-power excimer laser. To improve safety in clinical practice, understanding the pathological changes of tissues after excimer laser in lesions with ISR is essential.


Assuntos
Angioplastia a Laser , Reestenose Coronária , Animais , Humanos , Coelhos , Neointima/patologia , Lasers de Excimer/uso terapêutico , Artéria Ilíaca/cirurgia , Angiografia Coronária , Stents/efeitos adversos , Fibrina , Tomografia de Coerência Óptica/métodos , Reestenose Coronária/terapia , Resultado do Tratamento
8.
ESC Heart Fail ; 9(6): 4077-4087, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36043451

RESUMO

AIMS: Given the various effects of sacubitril/valsartan in heart failure, a deeper understanding of atrial natriuretic peptide (ANP) actions is warranted. Natriuresis is a fundamental action of ANP in acute heart failure (AHF), whereas the diuretic effect of ANP is different in each patient according to the diversity of renal response to ANP, which is affected by baseline plasma ANP status and deficiency of circulating ANP. Meanwhile, associations between other neuroendocrine hormones and the diuretic response to ANP are unclear. This study investigated the impact of pivotal neuroendocrine hormones on the diuretic effects of exogenous ANP, carperitide. METHODS AND RESULTS: Plasma ANP, renin, aldosterone, and vasopressin levels and the diuretic effect of 0.0125 µg/kg/min of carperitide alone for the first 6 h were prospectively evaluated in 75 patients with AHF. Lower ANP levels were significantly associated with a greater diuretic response to exogenous ANP (r = -0.35, P = 0.002). Additionally, higher vasopressin levels were significantly related to the poor diuretic effects of exogenous ANP (r = -0.54, P < 0.001). Plasma ANP and vasopressin concentrations were not significantly correlated (r = 0.19, P = 0.10). Baseline systolic blood pressure, renal function, and prior use of loop diuretics did not predict the diuretic response to exogenous ANP, whereas vasopressin levels independently predicted a diuretic response to exogenous ANP (P < 0.001), as well as lower plasma ANP levels (P = 0.027). CONCLUSIONS: Vasopressin status was significantly associated with the diuretic response to exogenous ANP in AHF, independent of plasma ANP status. The results may provide a better understanding of the actions of sacubitril/valsartan.


Assuntos
Diuréticos , Insuficiência Cardíaca , Humanos , Fator Natriurético Atrial , Diuréticos/farmacologia , Diuréticos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Valsartana , Vasopressinas , Sistemas Neurossecretores
10.
Heart Vessels ; 37(7): 1153-1161, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35050407

RESUMO

Managing right-sided chronic heart failure (CHF) due to tricuspid regurgitation (TR) remains a clinical challenge. Tolvaptan (TLV), a vasopressin V2 receptor inhibitor, is effective in controlling decompensated HF. However, its effects on right-sided CHF caused by TR are unclear. We sought to clarify the effects of TLV in CHF patients complicated with TR. The cohort consisted of 33 CHF patients with moderate or severe TR and permanent atrial fibrillation, who required hospitalization for HF. We observed 19 patients treated with TLV plus conventional therapies (TLV group) and 14 patients with conventional therapies alone (conventional group). Clinical characteristics, echocardiographic parameters, and laboratory data were investigated. Baseline characteristics were similar between groups. In the TLV group, the severity of TR at admission was 73.7% moderate and 26.3% severe. In the conventional group, these percentages were 85.7% and 14.3%, respectively. During the follow-up, the severity of TR improved in the TLV group (trivial-mild: 52.6%; moderate: 36.8%; severe: 10.5%) (p < 0.01). However, it did not improve in the conventional group (trivial-mild: 21.4%; moderate: 50.0%; severe: 28.6%) (p = 0.08). The diameter of the tricuspid annulus (p < 0.01), basal (p = 0.02), and mid right ventricle (p = 0.04) was reduced at follow-up in the TLV group. Nevertheless, these parameters did not change in the conventional group. Serum creatinine levels were maintained (p = 0.74) in the TLV group, but deteriorated in the conventional group (p = 0.03). TLV reduced right ventricular dimensions and improved TR without deterioration of renal function. Thus, TLV may be a new drug for the treatment of CHF patients with TR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Ecocardiografia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Ventrículos do Coração , Humanos , Tolvaptan/uso terapêutico , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/diagnóstico por imagem
11.
Circ Rep ; 3(9): 504-510, 2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34568629

RESUMO

Background: Antiplatelet therapy following stent implantation in patients requiring oral anticoagulation (OAC) is controversial because triple therapy (i.e., dual antiplatelet therapy [DAPT] with OAC) is associated with a high risk of bleeding. Methods and Results: In this study, 21 rabbits were divided into 5 groups: prasugrel and warfarin (Prasugrel+OAC group); aspirin and warfarin (Aspirin+OAC group); prasugrel, aspirin, and warfarin group (Triple group); prasugrel and aspirin (Conventional DAPT group); and no medication (Control group). The treated groups were administered medication for 1 week. An arteriovenous shunt loop was established from the rabbit carotid artery to the jugular vein and 2 bare metal stents were deployed in a silicone tube. After 1 h of circulation, the volume of thrombi was evaluated quantitatively by measuring the amount of protein. Bleeding time was measured at the same time. The volume of the thrombus (amount of protein) around stent struts was lowest in the Triple group, followed by the Prasugrel+OAC and Conventional DAPT groups, and was highest in the Control group. Bleeding time was the longest in the Triple group, followed by the Aspirin+OAC, Prasugrel+OAC, Conventional DAPT, and Control groups. Conclusions: This study suggests that prasugrel with OAC may be a feasible antithrombotic regimen following stent implantation in patients who require OAC therapy.

12.
Cardiovasc Interv Ther ; 36(1): 104-110, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32166728

RESUMO

There is no established hemostasis method or protocol for the transdistal radial approach. Therefore, this study aimed to determine whether "the PreludeSYNC DISTAL" radial compression device (PSD; Merit Medical Systems, Inc., South Jordan, UT) can effectively prevent distal radial artery (dRA) occlusion following catheterization procedures. This retrospective study analyzed patients who underwent hemostasis using the PSD from January 1, 2019, to March 31, 2019. The primary endpoint was occlusion or excessive stenosis of the radial artery (RA) 1 month after catheterization. Pulsatile blood flow and vessel diameters of the dRA and forearm RA (fRA) were measured using vascular ultrasound before and 1 month after catheterization to determine arterial damage. Secondary endpoints were achievement of hemostasis, bleeding, hematoma, aneurysm, neurological abnormality, and functional disturbance of the fingers or hand. Fifty patients (mean age, 70.9 ± 10.7 years; male, 72.0%) were enrolled in this study. Complete hemostasis was achieved in all cases. Total hemostasis time was 161 ± 45 min. No procedure-associated complications were noted. Pulsations of the dRA and fRA were maintained at 1 month. No functional disturbance or neurological abnormality was observed. Vessel diameters of the dRA and fRA were not significantly different before and 1 month after catheterization. No dissection, pseudoaneurysm, or occlusion/stenosis was observed on ultrasound. Distal radial access with a unique device and protocol effectively achieved hemostasis and prevented injury and occlusion of the dRA and fRA.


Assuntos
Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Doença da Artéria Coronariana/cirurgia , Técnicas Hemostáticas/instrumentação , Ultrassonografia/métodos , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Artéria Radial , Estudos Retrospectivos
13.
ESC Heart Fail ; 7(6): 4172-4181, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33037750

RESUMO

AIMS: Exogenous atrial natriuretic peptide (ANP) may be a logical treatment for heart failure (HF) patients with ANP deficiency. Lower ANP concentrations may result from HF with preserved ejection fraction (HFpEF), which also results in lower brain natriuretic peptide levels in HFpEF relative to HF with reduced ejection fraction (HFrEF), although clinical features regarding circulating ANP in HFpEF and HFrEF have not been fully investigated during acute HF. Here, we characterized the differential regulation of circulating ANP and the efficacy of exogenous ANP (carperitide) in patients with acute HF, especially HFpEF. METHODS AND RESULTS: Serum ANP levels before treatment and the diuretic effect of 0.0125 µg/kg/min of carperitide alone for the first 6 h were prospectively evaluated in 113 patients with acute HF who were divided into two groups: HFpEF vs. HFrEF. We mainly analysed the impact of baseline ANP levels and the presence of HFpEF on the diuretic effect of exogenous ANP. There was an inverse relationship between ANP levels and the diuretic effect of exogenous ANP (r2  = 0.19, P < 0.001). Patients with HFpEF had lower ANP levels (P < 0.001) and a greater diuretic effect of exogenous ANP than patients HFrEF (P < 0.001). HFpEF was an independent predictor of greater diuretic effect of exogenous ANP (P = 0.003), as with a lower baseline ANP level (P = 0.004). CONCLUSIONS: Patients with HFpEF might have an aspect of ANP deficiency and represent a promising therapeutic target for modulating circulating ANP.

14.
J Am Heart Assoc ; 9(19): e016595, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-32964759

RESUMO

Background Dialysis is an independent risk factor for in-stent restenosis (ISR) after stent implantation in coronary arteries. However, the characteristics of ISR in patients undergoing dialysis remain unclear, as there are no histological studies evaluating the causes of this condition. The aim of the present study was to investigate the causes of ISR between patients who are undergoing dialysis and those who are not by evaluating tissues obtained from ISR lesions using directional coronary atherectomy. Methods and Results A total of 29 ISR lesions from 29 patients included in a multicenter directional coronary atherectomy registry of 128 patients were selected for analysis and divided into a dialysis group (n=8) and a nondialysis group (n=21). Histopathological evaluation demonstrated that an in-stent calcified nodule was a major histological characteristic of ISR lesions in the dialysis group and the prevalence of an in-stent calcified nodule was significantly higher in the dialysis group compared with the nondialysis group (75% versus 5%, respectively; P<0.01). On the other hand, the prevalence of an in-stent lipid-rich plaque was significantly lower in the dialysis group compared with the nondialysis group (0% versus 43%, respectively; P=0.03). In all cases with an in-stent calcified nodule, the underlying calcification before stent implantation was moderate to severe. When tissue characteristics were stratified according to duration post-stent implantation, an in-stent calcified nodule in the dialysis group was mainly observed within 1 year after stent implantation. Conclusions In-stent calcified nodules are a common cause of ISR in patients undergoing dialysis and are observed within 1 year after stent implantation, suggesting different causes of ISR between patients undergoing dialysis and those who are not.


Assuntos
Aterectomia Coronária , Calcinose , Reestenose Coronária , Vasos Coronários , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea , Diálise Renal , Idoso , Aterectomia Coronária/métodos , Aterectomia Coronária/estatística & dados numéricos , Calcinose/diagnóstico por imagem , Calcinose/patologia , Angiografia Coronária/métodos , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Diálise Renal/efeitos adversos , Diálise Renal/estatística & dados numéricos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença
16.
Ann Noninvasive Electrocardiol ; 25(1): e12695, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31553117

RESUMO

BACKGROUND: ST-segment deviations in an initial 12-lead electrocardiogram provide anatomical information in ST-elevation myocardial infarction (STEMI). A diagnostic flowchart was formulated to estimate the anatomical characteristics of a culprit left anterior descending artery (LAD). METHODS: The present study analyzed 252 STEMI patients whose culprit lesions were confirmed to be LAD as an observational study. LAD morphology, wrapped (n = 26) or not (n = 226), and the positional relationship to first diagonal branch (n = 162 in proximal, n = 90 in distal lesions) were assessed. Their ST-segment deviations and such anatomical characteristics were examined. RESULTS: Reciprocal ST depression in nonwrapped LAD was frequent in patients without diagonal branch flow (49.3%-18.8% in II, p < .01; 66.4%-36.3% in III, p < .01; 63.7%-30.0% in aVF, p < .01). ST elevation in inferior leads was the characteristics of wrapped LAD but was not the case in patients without diagonal flow (50%-0% in II, 60%-0% in III, and 60%-0% in aVF). ST elevation in lateral leads to the diagonal branch in nonwrapped LAD is more frequent for proximal than distal lesions (36.3% vs. 15.0% in I, p < .01; 50.7% vs. 16.3% in aVL, p < .01), but this was not observed for wrapped LAD (18.8% vs. 20.0% in I, p = .72; 31.3% vs. 10.0% in aVL, p = .21). Positive and negative predictive values for the diagnostic accuracy of suggested diagnostic flow based on the above results were 0.794 and 0.478, respectively. CONCLUSIONS: Our suggested diagnostic flowchart provides enough diagnostic accuracy to estimate culprit morphology.


Assuntos
Vasos Coronários/fisiopatologia , Eletrocardiografia/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Idoso , Vasos Coronários/anatomia & histologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Int Heart J ; 58(3): 328-334, 2017 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-28484119

RESUMO

This study was conducted to assess whether any relationships exist between glucose fluctuations and electrocardiographic surrogate markers of reperfusion injury in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).We prospectively studied 63 consecutive patients with STEMI undergoing primary PCI. Patients had either diabetes (n = 30), impaired glucose tolerance (n = 26), impaired fasting glucose (n = 1), or normal glucose tolerance (n = 6). STsegment resolution (STR, %) was measured using electrocardiograms recorded 60 minutes after PCI. STR was categorized as ≥ 30% and < 30%. Glucose fluctuations were assessed by the following parameters obtained from a continuous glucose monitoring system: mean amplitude of glucose excursion (MAGE, mg/dL); and area under curve with reference to mean blood glucose (AUCMBG, mg/ dL/day).Both MAGE and AUCMBG were significantly higher in STR < 30%. In univariate analysis, MAGE ≥ 70 mg/dL (OR = 17.0; 95%CI, 1.93-150.12; P < 0.01), AUCMBG ≥ 20 mg/dL/day (OR = 10.9; 95%CI, 1.92-61.77; P < 0.01), and reperfusion arrhythmias (OR = 7.6; 95%CI, 1.32-44.29; P < 0.05) were significantly associated with suboptimal STR. Multiple logistic regression analysis showed only MAGE ≥ 70 mg/dL was predictive of suboptimal STR (OR = 22.5; 95%CI, 2.43-208.66, P < 0.01).Parameters of glucose fluctuations correlated with electrocardiographic surrogate markers of impaired myocardial salvage in STEMI after reperfusion therapy. Our results suggest that glucose fluctuations may represent a potential therapeutic target to reduce myocardial reperfusion injury in STEMI.


Assuntos
Glicemia/metabolismo , Circulação Coronária/fisiologia , Eletrocardiografia , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Idoso , Biomarcadores/sangue , Angiografia Coronária , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo
19.
Kyobu Geka ; 69(10): 876-9, 2016 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-27586322

RESUMO

A 57-year-old woman with Marfan syndrome had undergone the surgical treatment for pectus excavatum at 15 years of age. She had since been screened regularly by computed tomography(CT) to detect any vascular diseases. CT demonstrated a left subclavian arterial aneurysm at 55 years of age. It enlarged to a diameter of 32 mm, and surgical treatment was performed. The subclavian artery and the aneurysm were identified by echography in order to locate the exact sites of supraclavicular and subclavicular skin incisions. The subclavian artery aneurysm was resected without dividing the clavicle, and replaced by a vascular graft. Echography is useful for precisely locating a subclavian artery aneurysm, which enables feasible resection without dividing the clavicle.


Assuntos
Aneurisma/cirurgia , Síndrome de Marfan , Artéria Subclávia/cirurgia , Aneurisma/diagnóstico por imagem , Clavícula , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Artéria Subclávia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
20.
Masui ; 65(12): 1248-1254, 2016 12.
Artigo em Japonês | MEDLINE | ID: mdl-30379464

RESUMO

Thyroid storm is a rare, life-threatening condition characterized by severe manifestations of thyrotoxico- sis. Acute heart failure is one of the well-known com- plications of thyrotoxicosis. Thyrotoxicosis-induced heart failure sometimes causes circulatory collapse with high mortality. A 43-year-old woman had palpitations and exertional dyspnea without medical history. She developed con- gestive heart failure, due to tachycardiac atrial fibrilla- tion with no acute ischemic changes. High serum level of FT3 and FT4, and low level of TSH were shown in thyroid function tests, and thyromegaly in carotid ultrasound test She was admitted to the intensive care unit for acute heart failure caused by thyroid storm. Two days after admission, cardiopulmonary resuscitation and endotracheal intubation were necessary due to sudden cardiac arrest Transthoracic echocardiogram showed normal cardiac function after successful resuscitation. Five days after admission, her condition deteriorated with severe cardiac dysfunction, and she received PCPS (percutaneous cardiopulmonary support) for cardiovascular collapse resulting in persistent tachy- cardiac atrial fibrillation. Ten days after initiation of PCPS, the patient's cardiovascular function improved with estimated left ventricular ejection fraction of 50 percent and she was weaned off PCPS. In the case of acute heart failure with untreated hyperthyroid and refractory atrial fibrillation, careful hemodynamic management is required to avoid cardio- vascular collapse.


Assuntos
Insuficiência Cardíaca/etiologia , Crise Tireóidea/complicações , Adulto , Reanimação Cardiopulmonar/métodos , Dispneia , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Choque/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...